This series product department uses newest sheet piece the new product that development of machine technology development gives, it can spend sensor form a complete set with isotherm of the thermocouple of all sorts of different graduation date, thermal resistance, but with other DDZ-III model, composition of appearance of DDZ-II dynamoelectric and unit combination controls a system. Apply extensively already at industry now the changeover of signal of temperature of process of each domain production.
Product technology parameter
|
Renown Say
|
Say Bright
|
|
Indication intrinsic error
|
≤0.5%FS±1dig |
|
Be defeated
Go out
Special
Quality
|
Relay is outputted
|
3A/220VAC, 3A/24VDC
When relay outputs contact to receive perceptual load, two end must receive load scintilla draws circuit; And take carry ability to decrease accordingly.
|
|
Imitate changes send output (DC)
|
≥1KΩ of laden resistor of ≥1KΩ);1~5V(of laden resistor of <750Ω);0~5V(of laden resistor of <1.5KΩ);4~20mA(of 0~10mA(laden resistor) |
| Power source output |
24VDC/50mA or 24VDC/100mA (two) distribution output |
|
Communication interface
|
Interface standard
|
RS485(user can appoint RS232) |
|
Deferent means
|
Half duplex operation |
|
Frame format
|
A start bit, 8 digit are occupied, 1 stops |
|
Deferent rate
|
300~9600bps, parameter but set |
|
Online stage is counted
|
Most 31, address parameter but set |
|
Network structure
|
3 lines (or 2 lines) network of much chance communication |
|
Internal temperature is compensated
|
0~50 ℃ (undertake compensating by 0 ℃ when <0 ℃ ) |
|
Use environment
|
Environmental temperature
|
0~50 ℃ |
|
Environmental humidity
|
≤90%RH |
|
Power supply source
|
Power supply source
|
Power source of switch of 220AC, 220VAC()
24VDC(switch power source) or the user is special requirement
|
|
Power comsumption
|
≤6W |
|
Heavy Quantity
|
≤400g |
This series product is main characteristic and function:
1, Adopt set of simple soft, hardware, can wait for parameter to undertake choosing set to inputting type of signal of graduation date, span, output, all set parameter all but permanent save, and drop report not to lose data.
2, Can take segregation serial communication interface, transmission rate can adopt key-press freedom set, can input with all sorts of belts/ the equipment that exports communication function has two-way news report, comprise a network to control a system.
3, Each set parameter and debug parameter to be able to be decided with password lock, after the lock is piled up, can prevent to be operated by accident
Product type selecting is expressed
|
Model Chart
|
Say Bright
|
|
Model
|
DBW-
|
|
Product model |
|
Type
|
|
1
|
|
Odd loop |
|
2
|
|
Double loop |
|
Input signal
|
|
XY
|
|
X= the 1st road, Y= the 2nd (detailed sees a table one) |
|
Output signal
|
|
XY
|
|
X= the 1st road, Y= the 2nd (detailed sees a table 2) |
|
Power supply means
|
|
A
|
|
220VAC power source |
|
D
|
|
24VDC power source |
|
Communication means
|
|
P
|
|
Take RS485 communication interface |
|
Appearance structure
|
|
B
|
- |
The wall registers form |
|
C
|
- |
Slideway inserts outfit type |
|
G
|
- |
Wear outfit type |
|
Measure range
|
|
|
Measure range (the user is set oneself) |
Input signal type (express one) :
|
Signal code
|
Input graduation date
|
Measure range
|
Unit
|
Fully Note
|
|
1
|
Thermal resistance Cu50 |
- 50.0~150.0
|
℃
|
Thermal resistance electric current: 0.25mA (100Ω/0 ℃ )
Resistor of the biggest lead: ≤10Ω
|
|
2
|
Thermal resistance Cu100 |
- 50.0~150.0
|
|
3
|
Thermal resistance Pt100 |
- 199.9~500.0
|
|
4
|
Thermocouple B |
0~1800
|
400 ℃ are the following not plan measure precision |
|
5
|
Thermocouple S |
0~1600
|
200 ℃ are the following not plan measure precision |
|
6
|
Thermocouple E |
- 100~600
|
B: 400 ℃ do not measure precision below
S: 200 ℃ do not measure precision below
R: 200 ℃ do not measure precision below
Input resistor: ≥106Ω
Resistor of the biggest lead: ≤100Ω
|
|
7
|
Thermocouple K |
0~1300
|
|
8
|
Thermocouple J |
- 100~1000
|
|
9
|
Thermocouple T |
- 100~400
|
|
A
|
Thermocouple R |
0~1700
|
|
B
|
Thermocouple N |
0~1300
|
|
C
|
WRe3-WRe25 |
0~2300
|
|
D
|
WRe5-WRe26 |
0~2300
|
Output signal type (express 2) :
|
Code
|
Say Bright
|
|
10
|
First road 0~10mA output, the 2nd loop does not have output |
|
20
|
First road 4~20mA output, the 2nd loop does not have output |
|
11
|
The first, 2 loop: 0~10mA output |
|
21
|
First road 4~20mA output, 0~10mA of the 2nd loop is outputted |
|
12
|
First road 0~10mA output, 4~20mA of the 2nd loop is outputted |
|
22
|
The first, 2 loop: 4~20mA output |
|