| One, product brief introduction |
Power cable is used be defeated by distribution system, the communication that our company produce is rated cable of power of insulation of voltage 0.6/1KV pvc and 35KV and cable of power of polyethylene of the following cross-linking, its function accords with standard GB1276 and IEC60502 and IEC60840 not only, and already formed series, namely flame retardant model, fireproof model, cold-resistant and waterproof model power cable.
Be in flame retardant model in series product, used the technology that lie between oxygen successfully, not only the polyvinyl chloride insulation of 0.6/1KV and cross-linking polyethylene insulation are flame retardant power cable can achieve GB/T12666.5 " become bundle of power cable to burn experiment method " in A kind, and rated voltage 6/10KV and 8.7/15KV cross-linking polyethylene are flame retardant power cable also can achieve A kind tall flame retardant requirement and bigger abundant is spent. Be isolated from in cross-linking polyethylene tall low smoke was developed not to have bittern again on flame retardant foundation tall flame retardant cable of power of the layer that lie between oxygen, its are low smoke accords with national level GB/T17651.1.2 and GB/T17650.1.2 without bittern function. The integral level of cable of such our company cross-linking polyethylene power precedes under home position.
What our company produce is fireproof model power cable is cable of core of copper of rated voltage 0.6/1KV, still can produce low smoke not to have bittern fireproof power cable, tall flame retardant the layer that lie between oxygen is fireproof power cable, its are fireproof function accords with GB/T12666.6 " wire cable is fireproof and characteristic experiment method " . Accordingly, the integral function of cable of fireproof series power is admirable and reliable.
The block water property of fire prevention cable accords with IEC502-2 to set.
|
| 2, name and the model of cable, utility
|
|
Serial number
|
Model
|
Name
|
Scope of application
|
|
1
|
VV VLV
VY VLY
|
Pvc of polyvinyl chloride insulation / cable of polyethylene jacket power
|
Lay indoors, in channel and conduit, cable cannot bear action of mechanical outside force
|
|
VV22 VLV22
VV23 VLV23
|
Pvc of polyvinyl chloride insulation / polyethylene jacket metal strip is armored power cable
|
Lay indoors, soil is buried continuously inside channel, cable can bear action of mechanical outside force.
|
|
VV32 VLV32
VV33 VLV33
VV42 VLV42
VV43 VLV43
|
Pvc of polyvinyl chloride insulation / polyethylene jacket steel wire is armored power cable
|
Lay in tall fall area, cable can bear action of mechanical outside force and the pulling force that comparative.
|
|
2
|
YJV YJLV
YJY YJLY
|
Pvc of cross-linking polyethylene insulation / polyethylene jacket metal strip is armored power cable
|
Lay indoors, in channel and conduit, cable cannot bear action of mechanical outside force.
|
|
YJV22 YJLV22
YJV23 YJLV23
|
Pvc of cross-linking polyethylene insulation / polyethylene jacket metal strip is armored power cable
|
Lay indoors, soil is buried continuously inside channel, cable can bear action of mechanical outside force.
|
|
YJV32 YJLV32
YJV33 YJLV33
YJV42 YJLV42
YJV43 YJLV43
|
Pvc of cross-linking polyethylene insulation / polyethylene jacket steel wire is armored power cable
|
Lay in tall fall area, cable can bear action of mechanical outside force and the pulling force that comparative.
|
|
| Note: ZR- is flame retardant G- lies between oxygen layer NH- is fireproof |
|